Compliance
- Australian Standards AS 1735.18 (private residences)
- European Lift Directives
Passenger Protection
- FULL HEIGHT LIGHT RAY (180 beam) protection is standard
Drive Mechanism & Power Requirements
- Roped Hydraulic
- Single Phase 20amp
- Backup Batteries cause the lift to automatically lower to lowest floor and unlock its doors in the event of a power failure
Car Sizes
- Custom sizes to suit
- BCA E3.6 compliant size available for those of limited mobility/wheelchairs
- Maximum width 1200mm
- Maximum depth 1500mm
Capacity & Speed
Floors Served & Travel
- Maximum floors: 6
- Maximum travel: 12000mm
Opening to Lift Car
- Front/ single entry
- Opposite through car
- Adjacent through car
- Maximum openings: 2 under Australian Standards
Machine room location
- A space 900mm (wide) x 450mm (deep) x 1800mm (high) is usually required up to 7000mm away from the shaft at the landing of choice. Please discuss with your designer as smaller space options are available
Control
- Automatic operation
- Key isolation to the call and send functions
- Automatic return to false or nominated floors (optional)
- Limited mobility access features including braille (optional)
- Security features (optional)
|
|
Doors on landings
- Automatic or partially automatic swing doors
- Huge range of finishes to select from including stainless steel and panoramic glass doors
- Made from steel or anodised aluminium
- Range of door widths (500mm – 1100mm) in 50mm increments
- Jamb is additional 100mm on either side and above
- Fire rating 1 or 2 hour (optional)
- Remote control opening (optional)
- Different possibilities on different landings (mix and match)
Landing Buttons
- Illuminated and included in door jamb as standard
- Separate button box at nearby location (optional)
- Security features (optional)
- Up to 60 metres away infra-red remote calling (optional)
- Arrival indication included as standard
Cabin Finishes
- Select from our huge range
- Custom cabins available
- Glass walls (optional)
- Mirror walls (optional)
- Handrails (optional)
- Includes telephone (regular or hidden auto dialler option)
- Standard ceiling height of 2100mm (reduced is optional)
Building requirements
- Pit 130mm
- Pit 150mm for heavy or thick floor (optional)
- Headroom (finished floor level at top floor to inside top of shaft) 2500mm
- REDUCED HEADROOM OF 2400mm (optional)
Steel Shaft Structure (optional)
- see shaft section
- Select from our huge range of colours
- Aluminium and steel is available
- Glass (clear, tinted, white milk, reflecting, dark grey) is optional
|